The wire should be attached to each post for the best results.
Electric fence grounding options.
Most fences will require two or three grounding rods positioned about 10 ft.
The grounding rod for electric fence wire should be around 4 feet long.
Importance of grounding 8 electric fence grounding tips the most important part of setting up your electrobraid fence is installing a proper ground system.
How to install a more robust grounding system for an electric fence in poor grounding situations.
By using this system to ground the electrical fence the electricity is able to effectively shock the cow without the current traveling underground.
The electricity passes through the animal into the soil and back to the ground rods which are connected to the ground terminal of the fence charger.
These rods must be installed at least 10 feet apart from each other.
With a ground return design it is common for ground rods to be installed along the fence every 400 m 1300 to improve the grounding system.
If an animal touches both a hot and ground wire at the same time they close the circuit and receive a shock.
Apart near the starting point of the fence.
Frozen soil rocky soil dry soil.
In an electric fencing system electricity needs to complete a circuit in order to do its job.
A general rule is to install a minimum of 3 feet of ground rod per joule of output capacity.
A 15 joule fence charger will require a minimum of 45 feet of ground rod.
This design keeps electric fences working throughout the year.
The larger the output of a charger the more grounding rods will be needed.
An electric fence works by completing an electrical circuit whenever an animal touches the fence.
Fencing system is inadequate grounding.
If the rods are too close to the utility grounds they will cause interference in your phone or electrical lines.
Grounding rods can actually interfere with phone service as well as electrical lines that may be located on the property.
Drive the grounding rod at least 3 feet into the ground or all the way in leaving only 3 to 6 inches exposed above ground level.
If the power is not sufficient you may need to add another grounding rod to your electric fence grounding system.
Run a grounding wire parallel between the electric wires and drive a 4 to 6 foot galvanized steel or copper rod every 1 300 feet.
The importance of electrical flow before recommendations can be made as to the best type of grounding system to put on a fence its important to understand why one is needed and what can reduce its effectiveness.
In fact the majority of electrical fence systems will actually require at least three grounding rods.
Through the years we ve found that nearly 90 of all problems in an electric fence are the result of poorly or improperly installed grounds.